DOT-ClimaLogic® – Machine control
The proprietary control system for DOT environmental platforms
DOT ClimaLogic® is the control system developed in-house by Il Disgelo for the advanced management of climatic chambers, thermostatic chambers and complex environmental platforms.
Designed for industrial applications, laboratories and research environments, ClimaLogic® ensures process stability, test repeatability and complete data traceability.
It is the common platform across the entire DOT range
The digital core of DOT environmental platforms
ClimaLogic® was designed to manage complex environmental tests using advanced industrial control logic, ensuring:
-
long-term operational stability
-
repeatable test profiles
-
dynamic ramp management
-
integration with laboratory and production systems
-
continuous process data recording
The system operates consistently from stand-alone chambers to walk-in and multi-system installations.
System architecture
ClimaLogic® integrates a modular industrial architecture including:
-
dedicated industrial controller
-
DOT touchscreen operator interface
-
multi-parameter management (temperature, humidity, pressure, vibration, etc.)
-
industrial Ethernet communication
-
remote monitoring and control
The architecture is scalable and adaptable to the complexity of the equipment.
Industrial operator interface

The operator interface is designed to provide immediate control of test variables and machine status.
From the main screen, operators can monitor in real time:
-
measured temperature and humidity
-
active setpoints
-
refrigeration system status
-
operating modes (Manual / Program / Multi-Program / Remote)
-
machine status and alarms
A clear and intuitive interface reduces operational risk and simplifies daily testing activities.
Stable and Repeatable Control
ClimaLogic® is designed to maintain stable environmental conditions throughout the entire test cycle.
The system is optimized for:
-
controlled transitions
-
stable steady-state conditions
-
reliability during long-duration tests
This ensures consistent and repeatable environmental testing over time.
Multi-level user management

ClimaLogic® integrates a multi-level authentication system to ensure operational security and configuration protection.
Three access levels are available:
-
Operator → test execution and monitoring
-
Supervisor → program and parameter configuration
-
Service → maintenance and diagnostics
This approach ensures full traceability and controlled access to critical functions.
Test cycle management

ClimaLogic® enables the creation and management of automated test cycles:
-
program and multi-program selection
-
stored test profile library
-
automated test sequences
-
multi-phase test management
The programming environment is designed for complex and long-duration testing activities.
Advanced program configuration

The system allows configuration of:
-
delayed test start
-
number of repetitions
-
end-of-program behavior
-
automated test sequences
Ideal for continuous and cyclic testing.
Structured Test Cycle Programming
ClimaLogic® integrates a structured editor for creating multi-segment test cycles.
Each segment allows the definition of:
-
temperature set-point
-
relative humidity set-point
-
segment duration
-
ramp management
-
activation of auxiliary contacts
-
configuration of automatic sequences
The segment-based structure enables the creation of complex test profiles with high repeatability and precise control of transitions.
The management of repetitions and sequences allows the automatic execution of long-duration cyclic tests.
Multi-program and automated sequences

ClimaLogic® allows multiple programs to be executed automatically in sequence.
This enables:
-
long-duration unattended testing
-
automated test routines
-
complex testing workflows
Perfect for endurance and cyclic testing.
HMI configuration and customization

The system allows direct configuration of operational parameters, including:
-
language and interface settings
-
system date and time
-
data acquisition behavior
Designed for multi-user industrial environments.
Industrial connectivity and integration

ClimaLogic® is designed for integration into industrial networks.
The system allows:
-
Manual IP configuration or DHCP
-
Subnet, gateway, and DNS management
-
Integration into corporate networks
-
Industrial Ethernet communication
This allows the integration of control into Industry 4.0 architectures and external supervision systems.
Integrated maintenance and diagnostics

ClimaLogic® integrates preventive maintenance functions that allow you to monitor the status of the machine.
The system includes:
-
Hour meters for main components
-
Equipment status monitoring
-
Maintenance planning
This function reduces machine downtime and improves long-term reliability.
Advanced alarm management

The system allows the configuration of safety thresholds for process control:
-
configurable alarm thresholds
-
ON/OFF hysteresis
-
continuous monitoring of critical parameters
It guarantees protection of the material under test and operational continuity.
The digital heart of DOT solutions
ClimaLogic® is the proprietary control platform that ensures technological continuity across all DOT solutions, from standard chambers to special systems.